{"title":"Low VOC","description":"","products":[{"product_id":"low-voc-polyguard-85-clear","title":"PolyGuard 85 Low-VOC Polyaspartic Clear Top Coat","description":"\u003cp\u003eSurfacelogix® PolyGuard 85 Low-VOC Clear is an aliphatic, solvent-based, tinted polyaspartic system with 86% solids. Use the PolyGuard 85 Low-VOC Clear on its own or with full broadcast system coatings (pigmented and chip-embedded) for a durable, non-cracking, chemical- and tire mark-resistant finish with a glossy, “wet look” appearance. PolyGuard 85 Low-VOC Clear is ideal for use in garages, restaurants, service areas, and many other surfaces and can also be used on countertops, wood, and laminates. Its UV protection allows for outdoor applications without yellowing. \u003c\/p\u003e\n\u003cp\u003ePolyGuard 85 Low-VOC Clear is available in two-quart and two-gallon kits. Each kit includes two containers: one of Part A and one of Part B. Coverage: 125-250 square feet per\u003cbr\u003egallon.\u003c\/p\u003e\n\u003cp\u003eThe complete PolyGuard 85 Low VOC system consists of a pigmented base coating and a clear, high-gloss topcoat sealer. Base and Clear kits are sold separately.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePolyGuard 85 Low VOC Clear\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e(this product) is a high-gloss clear sealer specially designed as a topcoat for PolyGuard 85 Low VOC Base. \u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePolyGuard 85 Low VOC Base\u003c\/strong\u003e is a pigmented base coat designed to be top coated with PolyGuard 85 Low VOC Clear. Visit the\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/surfacelogix.net\/products\/low-voc-polyguard-85-base\" title=\"PolyGuard 85 Low-VOC Base\"\u003ePolyGuard 85 Low-VOC Base\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eproduct page to learn more.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Do not apply to pavers or very porous substrates. For professional use only!\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/9qDG7C7O-04?si=9nG4CMbasU8_vJSw\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eDirections\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003ePreparation:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eSurfaces must be clean and free of any contaminants before application. PolyGuard 85 Low-VOC’s performance is directly related to how thoroughly the surface is prepared. New concrete should cure for at least 28 days before applying. When applying directly on old concrete or coated surfaces, all cracks should be eliminated, and existing coating should be removed to provide a proper surface profile. To remove existing coating, sand\/grind the surface thoroughly with 60-grit sandpaper or diamonds. Test the product in an obscure area to ensure desired results for adhesion and finish. If humidity or moisture is suspected to be present in the concrete floor, a suitable moisture vapor barrier (MVB) must be applied. If a moisture vapor barrier is not in place, seasonal variations in ground moisture can cause excessive moisture vapor transmission (MVT), which can cause problems with the coating application. Recommended MVT rate for the PolyGuard 85 must not exceed 3 lbs. per 1,000 sq. ft. per 24 hours. The relative humidity (RH) of the slab must not exceed 75%. If there is a moisture situation in excess of the above rate, the use of a MVB primer like Surfacelogix® \u003ca href=\"https:\/\/surfacelogix.net\/products\/rapid-cure-mvb\"\u003eRapid Cure MVB\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eis recommended.\u003cbr\u003e\u003cstrong\u003eMixing:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eParts A and B of PolyGuard 85 Low-VOC must only be mixed together using a ratio of 1:1. Pour parts A and B into a clean, dry container and mix with a drill gently, avoiding creating air bubbles, for 3 minutes.\u003cbr\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eApply at a spread rate of 250–300 sq. ft. per gal. to yield 4-8 wet film thickness using a squeegee and back-roll with a non-shedding 3\/8” nap roller. A second coat may be desired. The second coat can follow after approximately 1 hour of dry time, depending upon weather and sun exposure. \u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eREAD LABEL THOROUGHLY BEFORE APPLYING PRODUCT\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eResources\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6508\/2173\/files\/PolyGuard_85_Low_VOC_Clear_Technical_Data_Sheet.pdf?v=1773760678\" title=\"Technical Data Sheet-English\"\u003eTechnical Data Sheet\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Surfacelogix","offers":[{"title":"Default Title","offer_id":51353868632381,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6508\/2173\/files\/PolyGuard85-Low-VOC-Clear-Kit.png?v=1779462296"},{"product_id":"low-voc-polyguard-85-base","title":"PolyGuard 85 Low-VOC Polyaspartic Tinted Base Coat","description":"\u003cp\u003eSurfacelogix® PolyGuard 85 Low VOC is an aliphatic, solvent-based, tinted polyaspartic system with 86% solids and is specially\u003cspan data-teams=\"true\"\u003e formulated for environments with strict VOC emissions requirements. The PolyGuard 85 system (base and clear) can be applied as-is or as part of a full broadcast system with pigmented and chip-embedded coatings to achieve a durable, chemical- and tire mark-resistant finish with a glossy, wet-look shine that resists cracking.\u003c\/span\u003e PolyGuard 85 Low-VOC is ideal for use in garages, restaurants, service areas, and many other surfaces and can also be used on countertops, wood, and laminates. Its UV protection allows for outdoor applications without yellowing. \u003c\/p\u003e\n\u003cp\u003ePolyGuard 85 Low-VOC Base is available in three-quart and three-gallon kits. Each kit includes three containers: two of Part A and one of Part B. Coverage: 150-200 square feet per gallon.\u003c\/p\u003e\n\u003cp\u003eThe complete PolyGuard 85 Low VOC system consists of a pigmented base coating and a clear, high-gloss top coat sealer. Base and Clear kits are sold separately.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePolyGuard 85 Low VOC Base\u003c\/strong\u003e (this product) is a pigmented base coat, designed to be top coated with PolyGuard 85 Low VOC Clear.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePolyGuard 85 \u003c\/strong\u003e\u003cstrong\u003eLow VOC Clear\u003c\/strong\u003e is a high-gloss clear sealer specially designed as a topcoat for PolyGuard 85 Low VOC Base. Visit the \u003ca title=\"PolyGuard 85 Low-VOC Clear\" href=\"https:\/\/surfacelogix.net\/products\/low-voc-polyguard-85-clear\/\"\u003ePolyGuard 85 Low-VOC Clear\u003c\/a\u003e product page to learn more and purchase\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Do not apply on pavers or very porous substrates. For professional use only!\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/9qDG7C7O-04?si=VRNDFoJIGYFQg3m4\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cspan\u003eProduct \u003c\/span\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e86% Solids\u003c\/li\u003e\n\u003cli\u003eCommercial Grade\u003c\/li\u003e\n\u003cli\u003eLow Odor\u003c\/li\u003e\n\u003cli\u003eNon-Yellowing\u003c\/li\u003e\n\u003cli\u003eUV Resistant\u003c\/li\u003e\n\u003cli\u003eHigh Gloss Finish\u003c\/li\u003e\n\u003cli\u003eExcellent Chemical Resistance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGarage floors\u003c\/li\u003e\n\u003cli\u003eRestaurants\u003c\/li\u003e\n\u003cli\u003eService areas\u003c\/li\u003e\n\u003cli\u003eCountertops\u003c\/li\u003e\n\u003cli\u003eWood\u003c\/li\u003e\n\u003cli\u003eLaminates\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDirections\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003ePreparation:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eSurfaces must be clean and free of any contaminants before application. PolyGuard 85 Low-VOC’s performance is directly related to how thoroughly the surface is prepared. New concrete should cure for at least 28 days before applying. When applying directly on old concrete or coated surfaces, all cracks should be eliminated, and existing coating should be removed to provide a proper surface profile. To remove existing coating, sand\/grind the surface thoroughly with 60-grit sandpaper or diamonds. Test the product in an obscure area to ensure desired results for adhesion and finish. If humidity or moisture is suspected to be present in the concrete floor, a suitable moisture vapor barrier (MVB) must be applied. If a moisture vapor barrier is not in place, seasonal variations in ground moisture can cause excessive moisture vapor transmission (MVT) which can cause problems to the coating application. Recommended MVT rate for the PolyGuard 85 must not exceed 3 lbs. per 1,000 sq. ft. per 24 hours. The relative humidity (RH) of the slab must not exceed 75%. If there is a moisture situation in excess of the above rate, the use of a MVB primer like Surfacelogix® \u003ca href=\"https:\/\/surfacelogix.net\/products\/rapid-cure-mvb\"\u003eRapid Cure MVB\u003c\/a\u003e is recommended.\u003cbr\u003e\u003cstrong\u003eMixing:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eParts A and B of PolyGuard 85 Low-VOC must only be mixed together using a ratio of 1:1. Pour parts A and B into a clean, dry container and mix with a drill gently, avoiding creating air bubbles, for 3 minutes.\u003cbr\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eApply at a spread rate of 250–300 sq. ft. per gal. to yield 4-8 wet film thickness using a squeegee and back-roll with a non-shedding 3\/8” nap roller. A second coat may be desired. The second coat can follow after approximately 1 hour of dry time, depending upon weather and sun exposure. \u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eREAD LABEL THOROUGHLY BEFORE APPLYING PRODUCT\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eResources\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003ca title=\"Technical Data Sheet-English\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6508\/2173\/files\/PolyGuard_85_Low_VOC_Base_Sell_Sheet_3-26.pdf?v=1774358456\"\u003eTechnical Data Sheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Surfacelogix","offers":[{"title":"Default Title","offer_id":51353872499005,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6508\/2173\/files\/PolyGuard85-Low-VOC-Base-Kit.png?v=1779462196"},{"product_id":"polyfill","title":"PolyFill Polyaspartic Crack Filler","description":"\u003cp\u003ePolyFill is a two-component, low-VOC compliant, 100% solids polyaspartic-polyurea crack filler. Use PolyFill to repair cracks, crevices, and other damage to concrete surfaces before applying \u003ca href=\"https:\/\/surfacelogix.net\/products\/polyguard-85\" title=\"PolyGuard 85\"\u003ePolyGuard 85\u003c\/a\u003e or other polyaspartic, epoxy, or polyurea coatings. PolyFill’s fast curing formula can allow for same-day crack repair and coating application. Easy to mix and apply, PolyFill is low odor and won’t expand or contract while curing. Once cured, the filler will become very hard yet flexible, resisting traffic and heavy loads while helping prevent future cracking and separation\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFOR PROFESSIONAL USE ONLY !\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e100% high solids, low VOCs\u003c\/li\u003e\n\u003cli\u003eHard, tough, yet flexible surface finish.\u003c\/li\u003e\n\u003cli\u003e1 Hour return time\u003c\/li\u003e\n\u003cli\u003eNo contraction; No expansion on curing\u003c\/li\u003e\n\u003cli\u003eHigh temperature and traffic resistance\u003c\/li\u003e\n\u003cli\u003eGreat chemical and stain resistance\u003c\/li\u003e\n\u003cli\u003eVery fast cure\u003c\/li\u003e\n\u003cli\u003eVery good adhesion to contentious substrates\u003c\/li\u003e\n\u003cli\u003eExcellent flow and leveling\u003c\/li\u003e\n\u003cli\u003eEasy to mix; easy to apply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cstrong\u003eDirections\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSurface Preparation: \u003c\/strong\u003eSurfaces must be dry and clean, and free of any contaminants before application (dirt, dust, oils, grease, or solvents should not be present). PolyFill’s adhesion and performance is directly related to how thoroughly the surface is prepared. Before applying, all cracks should be sanded\/grinded thoroughly, and brushed with a hard brush, and chips or loose concrete debris should be removed. Clean off all dirt and dust with a blower or use a vacuum machine to leave surface completely clean and dry. It is recommended to test product in an obscure area to ensure desired results for adhesion and finish. Coverage is approximately 200-300 linear feet per half gallon kit to fill 1\/8\" x 1\/8\" cracks but will depend on porosity of the substrate and shape of the cracks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMixing Instructions:\u003c\/strong\u003e Pour all of Part B directly into the Part A container and mix for 2-3 minutes with a spatula or slow RPM mixer\/drill. Avoid creating air bubbles. It is recommended to mix and use the entire kit at one time as parts A and B are pre-weighed to ease controlling the mixing ratios.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow to Apply:\u003c\/strong\u003e To apply, simply pour mixed PolyFill directly into the crack or apply with spatula, putty knife, or trowel. Note: PolyFill is fast curing and will harden within 15-20 minutes, so it is recommended to apply at once over the whole crack area  to allow for good penetration and leveling over the entire crack. Apply PolyFill leaving an excess or small dome over the crack, so when it hardens, it can be sanded down flat and level. For deep cracks, use a spatula to push down PolyFill mixture, making sure enough PolyFill has been added to completely fill all spaces and gaps. If a second application is needed to fill the crack, apply within an hour of the first application. After one hour, any excess filler can be removed by sanding or grinding to achieve a flat, even surface that is ready to be coated. Note: It is the sole responsibility of the applicator to determine whether PolyFill is appropriate for the job.\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Surfacelogix","offers":[{"title":"29 oz. Kit","offer_id":51644562899261,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false},{"title":"57.9 oz Kit","offer_id":51644562932029,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6508\/2173\/files\/PolyFill_29oz_Kit.png?v=1779984334"}],"url":"https:\/\/surfacelogix.net\/collections\/low-voc.oembed","provider":"Surfacelogix","version":"1.0","type":"link"}